Electrical Requirements

ETEC™ recommends using an uninterrupted power supply to protect your printer. All electrical requirements must be met to ensure the most stable setup:

  • Ensure there is a sufficient clean electrical socket that fluctuates no more than +/- 3% (EU: +/- 5%) from its baseline.

  • Do not plug any additional equipment into the power circuit.

  • The Envision One cDLM™ requires 110 volts with no less than 5 amps.

  • The oxygen concentrator requires 120 volts with no less than 3 amps.

  • Oxygen Concentrator needs:

    • Power supply of 220 V ± 22 V, 50 Hz ± 1 Hz/110 V ± 15 V, 60 Hz ± 1 Hz.

    • Operation voltage (V/Hz): AC 220/50 AC 110/60.

  • Plug the printer and oxygen concentrator into separate surge protectors or separate battery backups.

  • The Envision One cDLM printer does not require a dedicated server. It can be connected wirelessly, hard-wired into the network, or directly connected to a computer.

WARNING

Risk of electric shock: Connect the printer to grounded outlet ground wire before using. Only use the grounding adapters of the plug & socket type targeted for the country of intended use of the printer.